3 RJ45 Modbus-TCP/IP Protocol PAL I/O System Analog/ Digital DC24V input

Ask Latest Price
Video Channel
Brand Name :Olycom
Model Number :OM523E-1BL22-TCP
Certification :CE RoHS FCC
Place of Origin :Guangdong, China
MOQ :1 pc
Price :Negotiable
Payment Terms :T/T, PayPal
Supply Ability :5000pcs/month
Delivery Time :3~5 working days
Packaging Details :1pc in a box
Product name :PLC io module
Use :Industrol Control
Protocol :Modbus
IO Response Time :Minimum 500us
Working Voltage :24VDC (voltage range 18VDC~28VDC)
Sample :Available
Communication Interface :2*RJ45
Power Protection :Anti-reverse connection protection, surge absorption
Service :Support OEM/ODM
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

3 RJ45 Modbus-TCP/IP Protocol PAL I/O System Analog/ Digital DC24V input

Product Features of PAL I/O System

* 2 RJ45 interfaces, 100Mbit/s
* Bus, power isolation technology, and reliability
* Standalone as Modbus-TCP/IP slave station

Specification of 3RJ45 Modbus-TCP/IP I/O System

Model OM523E distributed scalable coupler
Technical Specifications
Operating Voltage 24VDC (18VDC~28VDC)
Operating Current Consumption Different product models vary, please refer to the product manual for details.
Power Protection Anti-reverse connection protection, surge absorption
Communication Interface 2*RJ45
Expansion Module interface 1*RJ45
Power Terminal Type Plug-in connectors, screw terminals
Signal Terminal Type Plug-in connector, direct plug-in PUSH-IN connection port
Display Instructions Power indicator light, NET green indicator light, SF red indicator light,IO signal green indicator light
Protocol Modbus-TCP/IP
Master-Slave Category Independent slave device
Ontology IO Point Yes, see ordering data for details
Overcurrent protection Threshold 1.5A,5ms
IO Response Time Minimum 5ms
Expansion Capabilities Supports expansion of 16 EM500E-EM modules
Cable Length (shielded) Maximum 500m
Cable Length (Unshielded) The longest input point is 300m, the longest output point is 150m
Slave Settings
IP Settings Set by DIP switch or web page
Maximum Number of Stations per Segment 255 (The specific number of supported stations is determined by the main station)
Working Environment
Working Temperature -20~60℃
Working Humidity 5%~90% (no condensing)
Protection Level IP20
Dimensions (L*W*H) 27mm*104mm*114mm

Ordering Details

Specification Product No.
OM521E vertical internal bus distributed expandable coupler, Modbus-TCP bus, 3 RJ45 ports, WellAUBUS backplane bus (blackRJ45 port network cable cascading, Category 5e network cable module length (limited to 20 meters), total extension cable total (limited to 150 meters), and 16 modules can be expanded.24VDC power supply, with 8-bit dial setting station IP address, the body comes with 32DI (common cathode/common anode input), IP20Protection level, supports DN35 rail installation

OM521E-1BL22-TCP

OM522E vertical internal bus distributed scalable coupler, Modbus-TCP bus, 3 RJ45 ports, WellAUBUS backplane bus (black RJ45 port network cable cascade, Category 5e network cable module length (limited to 20 meters), total extension cable total (limited to 150 meters) and can be expanded to 16 modules.24VDC power supply, with 8-digit dial code to set the station IP address, the body comes with 32DO (PNP output), IP20Protection level, supports DN35 rail installation

OM522E-1BL22-TCP

OM523E vertical internal bus distributed expandable coupler, Modbus-TCP bus, 3 RJ45 ports, WellAUBUS backplane bus (black RJ45 port network cable cascading, the length between Category 5e network cable module length (limited to 20 meters), total extension cable total (limited to 150 meters), and 16 modules can be expanded.24VDC power supply, with 8-bit dial setting station IP address, the body comes with 16DI (common cathode/common anode input), 16DO (PNP output), IP20 protection level, supports DN35 rail installation

OM523E-1BL22-TCP

Packing

3 RJ45 Modbus-TCP/IP Protocol PAL I/O System Analog/ Digital DC24V input

Production Steps:

  • Welding: Weld the necessary components
  • Cleaning: To avoid any possible dysfunction due to dust or scraps on the PCB boards.
  • Assembling: Builds up components of a product, like panels, screws, PCB boards.
  • Testing: To make sure the product is basically working fine after assembling
  • Aging: To check if the product can work smoothly for long time without any minors such as LED indicators, voltage. This will usually last for 24 to 48 hours.
  • Testing: To test if the product can process data or video signals correctly. Any data loss? Transmission rate correct? Any data packet failure? Such questions would be verified in this procedure.
  • QC testing: This is the third and also last check of product quality. If it goes good, our packing staff will pack it up according to customer requirements and attach to the packing box a product label.
  • When all above is done, the product will go to market.